(DI-2108) SCM system qRFC queue details

Collector /DVD/MON_CL_COL_QRFC has integrated monitoring for /SAPAPO/ function modules for SCM systems. As these function modules have a large number of parameters a separate input table is needed.

Input Table

Input table for SCM system /DVD/MON_APO_CF is slightly different from standard qRFC queue monitoring. Fields are:

Queue Name

Name of RFC queue

Destination

Destination of RFC queue. If left empty, it will be considered as Inbound queue.

Parameter Path

Path to a parameter which value you wish to monitor. There are 3 types of parameters:

  1. Single parameter - extracting the single value of the parameter - defined as IV_PARAMETER

  2. Struct parameter - extracting field value from a struct - defined as IS_STRUCT-FIELD

  3. Table parameter - extracting field value from a table - defined as IT_TABLE-FIELD

qRFC State

If left empty parameters will only extract if queue with provided specifications is i n SYSFAIL state. With this field user can specify if he wants to monitor queue in state other than SYSFAIL.

Custom Field

Defines where the parameter value will be stored in already existing Datavard Insights detail table /DVD/MON_S_QUEUE_ERROR.

  1. CUSVAL1-CUSVAL6 - suitable for single parameter/struct parameter values

  2. CUSLVAL1-CUSLVAL2 - long values, good for storing table field parameters as those represented in a single field as VALUE1;VALUE2;VALUE3;VALUE4 (when a table has multiple rows, values are separated by “;” in one field)

Detail Table

Output of SCM extraction will be appended into the existing detail table /DVD/MON_S_QUEUE_ERROR under CUSVAL fields user specified in the input table.