Collector /DVD/MON_CL_COL_QRFC has integrated monitoring for /SAPAPO/ function modules for SCM systems. As these function modules have a large number of parameters a separate input table is needed.
This part of the collector and its input table is only for SAP SCM systems.
Input Table
Input table for SCM system /DVD/MON_APO_CF is slightly different from standard qRFC queue monitoring. It provides the following fields:
Queue Name | Name of RFC queue |
---|---|
Destination | Destination of RFC queue. If left empty, it will be considered as Inbound queue. |
Parameter Path | Path to a parameter which value you wish to monitor. There are 3 types of parameters:
You can use F4 help to display SCM function modules and their parameters to choose from. |
Custom Field | Defines where the parameter value will be stored in already existing CrystalBridge® Monitoring detail table /DVD/MON_S_QUEUE_ERROR.
|
You might also define input values with wildcard '*' for fields Queue Name and Destination. Other field values have to be fully specified.
Detail Table
Output of SCM extraction will be appended into the existing detail table /DVD/MON_S_QUEUE_ERROR under CUSVAL fields user specified in the input table.