(SP21) FIX-006 ADSO post-activation fix
BUG FIX ARCHIVE
Download link
https://mats.datavard.com/downloader.php?ticketid=49bf3a179727598d81742d879f678e06
Description: Outboard DataTiering FIX-006 ADSO post-activation
Password: Datavard1
Transports requests
Request | Date | Owner | Short Text |
---|---|---|---|
HD1K903487 | 02.11.2018 | DATAVARD | Outboard DataTiering FIX-006 ADSO post-activation fix |
Import the transport request to the affected system.
ISSUE DESCRIPTION
For ADSO - Corporate memory, the post-activation Outboard DataTiering enhancement is triggered even though there is no NLS data on the system.
ERROR DESCRIPTION
Activation of load requests for an InfoProvider cannot be processed.
SOLUTION
A new check was implemented into the enhancement. It checks whether an InfoProvider is archived in NLS.