(DI-1711) Basis add-on setup

This setup is required first step after Fiori and ODATA services of Insights product were enabled in central system. This setup defines analyses that can be executed by Datavard Insights.

Adjusting monitored satellite system

To make scheduling of Basis module collectors possible on satellite system (i.e. system to be monitored) this system must be present in monitored system list and must have correct monitoring area assigned. For information how to add satellite system to list of monitored system see /wiki/spaces/ITOA/pages/4474634314. When satellite system is successfully added to the list of monitored systems, Basis module monitoring area must be assigned to it. To do this follow these steps:

  1. In /DVD/MON transaction for Insights monitor go to 'System Settings' (Shift + F5).
  2. Select system to be monitored by Basis module collectors.



  3. Double click on 'System mon. areas' in dialog structure tree. 
  4. Click on 'New Entries' (F5) button. 
  5. Add new entry with following value 'HMCCAE'.



  6. Press 'Enter' and save changes.
  7. It will be possible to schedule the Basis module collectors for this satellite system now. 

Analyses for Satellite System


Monitoring ProfileDescriptionDefault scheduling period
System SizeHMBS_E_SS

HM Basis: System size

Days: 1
HousekeepingHMBS_A_HK

HM Basis: Housekeeping analysis

Weeks: 1
HMBS_E_HK

HM Basis: Housekeeping ETL

Days: 1

For more detail information about how to setup Monitoring Profiles, check section /wiki/spaces/ITOA/pages/4474634314 (sub-section "Create a Collector job").