(SP38) PIT Recovery Troubleshooting
In this chapter, you can find troubleshooting scenarios and the solutions to resolve the encountered issues.
- Action table on storage is missing. The synchronization is not possible.
This issue may occur if the archive is restored to a point in time when it doesn't correspond with the primary database and you executed the synchronization process.
In this scenario, an archive has been restored to a state, where the PIT changelog on the primary database didn't exist yet.
In this case, it is possible to recover the archive, only if it has been restored to a point in time between the last supported action (archiving, reloading, change of structure, Writer operations) and the PIT changelog creation.