(DI-2205) Deletion of system ends up in dump/exceeds time limit.
When deleting the system from CrystalBridge® Monitoring cockpit a dump may occur when execution takes too long. This is caused by a huge volume of collected transaction data for the system. In that case, these data have to be deleted manually by smaller parts. Using SE38 execute report /DVD/MON_DATA_DELETE.
Screen options:
Time Selection - specify deletion by data time range. If deletion of system dumped, try to delete it by smaller time frames.
All data in time range - by default checked - will delete all transactional data in a selected time frame for each monitored system by CrystalBridge® Monitoring. If an unchecked user can specify:
System ID - user can manually select which system will be data deleted from
Tables - tables that contain CrystalBridge® Monitoring transactional data. This select option is pre-filled by default - do not change unless you know what you are doing
Test mode - when executed with test mode checked, none of the database data will be deleted, instead it will write a list of tables that would be deleted.