Datavard Insights Fiori monitored system overview (MSO) screen displays status of all monitored systems. This chapter describes where the data are comming from to the MSO and how can user customize it.
Monitored system list
List of displayed monitored systems and their assigments to the system groups is dependant on their definition in /DVD/MON transaction (Datavard Insights cockpit) of central system.
System group assigment
Each system defined in cockpit is also shown in MSO. As MSO is not capable to display systems in a tree view that is used in Cockpit transaction each system is assigned to exactly one group (folder) from top most level of system tree structure. By default the top most level of the tree structure is set to the root of the tree. Taking the previous picture as example the system EVI1000066 would be assigned and displayed under 'Datavard's systems' system group while system 09EE000058 would be assigned to 'NESTLE Landscape' system group.
User can change which folder of tree structure will serve as top most level by changing appropriate setting value using program '/DVD/HC_ODATA_SETTINGS'. By providing id of system group for parameter 'SYSTEM_GROUP_TOP'. Specified group will become top most level for all the users.
Example: If we would change parameter value to 'ALL_SYSTEMS' (Datavard's systems), system EV1I000066 would be assigned to 'Datavard' system group in Fiori MSO. All systems that are not direct children of set top most level are automatically assigned to aritificial group 'Not Assigned Systems'.
Administrator customizations per user
User (administrator) with access to the Insights Cockpit (under transaction '/DVD/MON') can setup filters per user. Using these filters systems and system groups can be excluded from MSO for specific users. To assign any user specific filter go to transaction /DVD/MON and choose 'System Settings'. Filter directly on systems can be setup in 'Filter for system ID'. Filter for whole system group can be setup in 'Filter for system group' section.
Once some customization is setup for user in 'System Settings' of Insights Cockpit it is always used as filter on appropriate object list. If there is filter of type 'Include' for one system the affected user will see only that system in MSO even that other systems are not explicitly excluded.
System status indicator
Each system in monitored system overview (MSO) has icon assigned that represents its status. System status is defined by following logic:
- System status is set to NaN.
- Check if system is available. If not ERROR status is set and processing is ended.
- Check if there are any running collector jobs for the system. If there is at least one running collector status is set to OK.
- Check all opened alerts for the system. Based on alert priority type appropriate system status is set.
Available system status available are displayed bellow sorted based on priority with least priority on left.
System status KPI
Each system in system overview (MSO) can have status KPI assigned. This KPI should reflect overall system health. To setup KPI that should be displayed in MSO for specific system user can go to 'System settings' of Insights Cockpit. Under 'System status KPI' option he can assign which KPI value should be displayed in MSO.
It is possible to override this setting for each user under 'System status KPI' option.
Each system status KPI value is accompanied by trend indicator. Indicator direction is determined by last two values of status KPI.