Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

One alert must be defined only for one KPI. In the case one alert is defined for multiple KPIs, the check finds this alert and creates copies of it, and assigns the newly created alerts to KPIs which were originally not correctly assigned to the one alert. The name of the newly created alert is created as prefix 'X' + name of the original alert + '_order number of the erroneous KPI'.

XPRA upgrade check execution

Go to the transaction SE38 and execute the report /DVD/MON_UPGRADE_CHECKS.

...

Image Added

The Test mode (first checkbox) doesn't perform any DB changes.

Output

Based on the option selected in the section Logs, you can display written or logged output.

If you execute the report while importing a transport to a system, we recommend using the write option.

...

Image Added

Write output (marked checkbox)

...


Image Added

Log output (empty checkbox)


Output from this check is available right after the report execution or in SLG1 after selecting:

Object: /dvd/mon

Subobject: /dvd/mon_checks

External ID: name of the check (can be empty to display all checks)

Double-click on the log to display further information.