BW module requires two more OData services to be registred on central system. See section Setup OData & Fiori for details how to register OData service. Odata services that should be registred in addition to standard Insights OData services can be found in General add-on information section.

Additional monitoring setup

...

To make schedulling of BW module collectors possible on satellite system (i.e. system to be monitored) this system must be present in monitored system list and must have correct monitoring area assigned. For information how to add satellite system to list of monitored system see /wiki/spaces/CC/pages/14040794Configure a Landscape. When satellite system is successfully added to the list of monitored systems, BW module monitoring area must be assigned to it. To do this follow these steps:

  1. In /DVD/MON transaction for Insights monitor go to 'System Settings' (Shift + F5).
  2. Select system to be monitored by BW module collectors.
    Image RemovedImage Added
  3. Double click on 'System mon. areas' in dialog structure tree. 
  4. Click on 'New Entries' (F5) button. 
  5. Add new entry with following value 'HMBW'.
    Image RemovedImage Added
  6. Press 'Enter' and save changes.
  7. It will be possible to schedule the BW module collectors for this satellite system now. 

...

  1. Run transaction /DVD/MON for Insights monitor.
  2. Switch to 'Collector Jobs' tab.
    Image Modified
  3. Click on 'Create collector job' button
  4. Fill following collector job settings:
    1. System ID - system where to run analysis (Insights BW module must be installed on the monitored system). This should be satellite system. 
    2. Monitoring profile - profile that specifies analyses to be run on the system. Currently BW module supports following profiles and their respective collectors:
      1. HMBW_1DAY profile with collectors:
        1. Data Distribution Collector
        2. Query Usage Collector
    3. Execution - time when first analysis run should be executed.
    4. Period - periodicity of collector job execution. This setting should follow these recommendations for monitoring profiles of BW module:
      1. HMBW_1DAY:
        1. Type: Days
        2. Value: 1
    5. Retention time- periodicity of KPI values deletion. This setting should follow these recommendations for monitoring profiles of BW module:
      1. HMBW_1DAY - 365 days
      Image RemovedImage Added
  5. Click on (Re)Start collector job button
  6. Newly created collector job will appear in table of all collector jobs with all the necessary informations regarding its execution status.
    Image RemovedImage Added