Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Current »

Standard DTP loads, where the source InfoProvider is offloaded ADSO, are currently not supported by OutBoard DataTiering on BW/4HANA systems.

It is possible to transfer already offloaded data on BW/4HANA systems by replacing the original DTP with a DTP from CompositeProvider that consists of the BAdI provider and the original ADSO:

  1. Create CompositeProvider and add the original ADSO into it.

  2. Execute /wiki/spaces/OFO/pages/747536413 for this ADSO.

  3. Create a BAdI provider and /wiki/spaces/OFO/pages/747274276 the CompositeProvider.

  4. Create a new transformation and DTP where a source is the CompositeProvider.

  5. Replace the original DTP in the data flows with the newly created DTP.

  • No labels