(DI-2305) Collector for BW Erroneous Process Chains

This collector monitors BW process chains that contain errors. The technical name of the collector is /DVD/MON_BW_CL_COL_PC.

Default KPIs delivered with this collector

The following default KPIs are delivered with this collector:

KPI name

Description

Unit

Detail table

KPI name

Description

Unit

Detail table

BW_PC_STEP_COUNT

BW: Process Chain step count

Number

Yes

BW_PC_STEP_ERR

BW: Process Chain step error

Number

Yes

Parameters

The following parameters are used for this collector:

Parameter name

Description

Parameter name

Description

MAX_CHECK_TIME

Default 3600 seconds (1 hour). Defines how far back in time should process chains be considered for this collector

Detail table

The collector provides detail tables of BW process chains with an error. The technical name of the detail table is /DVD/MON_BW_PCE. It contains process chains in error and provides fields:

Technical name

Description

Technical name

Description

TIMESTAMP

Timestamp with conversion routine to AS time-zone

SID

System ID

CHAIN_ID

Process Chain

OBJVERS

Object version

TYPE

Process Type

VARIANTE

Process Variant (Name)

TXTLG

Long description