When a Drill Down Test Case is added to the Test Plan a new backend Test Run is automatically created and a Run ID is generated. The description holds the technical name of the Test Plan and the Test Case. All Drill Down Variants selected during the creation of Drill Down Test Case are automatically added into Drill Down Variant selection for the generated Test Run.
To execute a Drill Down Test Case from Test Management click on 'Execute' afterwards the standard Drill Down Testing scenario is displayed. Please refer to 8.3.1 ('Test Scenario EQS_DRILL (Drill Down testing)') section for a more detailed description about each scenario step.
Drill Down testing
The KATE Validate Drill Down Test Scenario uses the ListCube functionality in a similar way as in the ListCube test scenario and uses the RSA1 'Display Data' functionality to get the data from the InfoProviders to be tested.
Recommendations:
- For one DrillDown testing run, a maximum of 1000 Drill Down variants should be used.
- It is recommended to use of the KATE Validate setting 'DrillDown maximum records' to under the value of 100 in order to reduce the amount of data to process and reduce the chance of errors.
...
You can select which of the Drill Down Variants are to be used or create new Drill Down Variants to be added into the Test. When the Test Run is generated through the KATE Validate Test management the variants are already preselected for the Drill Down Test Case.
Once the variants are selected for the Test Run, you can save the selection by clicking on 'Save' button (Ctrl + s).
In the following ways it is possible to add Drill Down Variants to the list:
Create New Drill Down Variant - (SHIFT + F1). For detailed information about creation of Drill Down variant please refer to 7.4.1 ('Create new Drill Down Variant ') section,
Add Existing Drill Down Variant - (SHIFT + F4) displays all of the existing Drill Down Variants in the system, and you can select one or more variants to be added into the current Test Run.
Add Drill Down Variants of Run - (SHIFT + F5) you can select the Variants used in another (distinct from current) run and add them into current the run as well.
Generate Drill Down Variants - (SHIFT + F6) please refer to 7.4.2 ('Generate Drill Down Variants') section for more information.
Copy Variants - Please refer to7.1.14 7.4.7 ("Copy DrillDown Variants") section for function details.
...
In the third scenario some or all data returned by InfoProviders are not same. In this case a new test cycle begins, and the erroneous data is checked. Using the KATE Validate setting 'DrillDown maximum records', for the first added characteristic (the one added at the start of first cycle) the X number of distinct values that belongs to erroneous records are the selected. These values act as a filter value for this characteristic in next test cycle (drill down into erroneous records).
The next characteristic in the order of specified Drill Down characteristics (if no more are available then the execution stops here) is added to ListCube for reading and then another characteristic is selected for the output. The ListCube reads are repeated for both InfoProviders with the new settings and the data is then compared again. Afterwards either a new test cycle begins using the same logic just described, or execution ends here, depending on the result of comparison.
If KATE Validate setting 'DrillDown additional aggr.' is set to 'X' in each cycle when InfoProviders are read the returned data is aggregated again. This functionality can be used for cases when ListCube returns multiple rows with same key because of unsupported functions.
...