  • Max. package number (DTP) - determines the maximum number of packages which can be processed at once in the loading via a Data Transfer Process (DTP).
    Possible values: integer > 0 e.g. 10, 20, 50
    Default value: 5
  • Finished packages for processing - maximum number of finished processes during parallel DTP load.
    Possible values: integer > 0 e.g. 10, 20, 50
    Default value: 2
  • Parallel jobs for loading – determines how many parallel jobs will be used for reading from the archive when loading from the archive via DTP. (link to further reading).
    Possible values: integer >= 0 e.g. 0, 4, 15
    Default value: 0 (no parallelization)
  • Parallel WP for reporting – this value determines how many work processes are used for reading when data from OutBoard is requested for reporting. For more information see Reporting on archived data.
    Possible values: integer > 0 e.g. 10, 20, 50
    Default value: 0 (no parallelization)
  • Filtering type – determines the filtering logic when accessing the NLS data.
    Possible values: SETS, RANGE

Expert settings

There is also possibility for users to enter Expert settings. These settings have the form of the database table and have also parameters not visible in Main settings. 
Each parameter can be either InfoProvider-specific (these can vary between different InfoProvider) or is set only globally. A special InfoProvider is used which is called "DEFAULT". If no parameters are set on InfoProvider level, the DEFAULT value is used.  Global parameters may only be set in the DEFAULT.

Note

If DEFAULT parameter value is changed, values for all InfoProviders, for which a value was not explicitly set, will change as well

Output from Settings

Parameters

  • AUTHORIZATION – this parameter determines if OutBoard Authorization is switched ON (value X) / OFF (value ' ')
    Default value: OFF
  • BG_JOB_DIRECT_START – this parameter determines if Background jobs in OutBoard are started "With converting to Time – Based Jobs" (value 'X')/ "Without converting to Time – Based Jobs" (no value). When job is started "Without converting to time based jobs", this job is scheduled and started normally, when any background job is free. When selecting "With converting to Time – Based Jobs", the job will be started immediately if any background job is free, if there are no free background jobs it will try to execute the job every ten seconds for 30 minutes.
    Default value: OFF.
  • CURRENCY – the currency in which money saved is calculated.
    Possible values: Any currency available in SAP.
    Default value: EUR
  • DATA_CLASS – determines the Data Class for storage table and its indexes. It can be changed only when no data is archived. For Oracle database the tablespace for particular storage table can be selected. It is determined by DATA_CLASS. The link between a tablespace and Data Class can be found in table TAORA.Possible values: Any Data Class available in SAP system.
    Default value: APPL1
  • DISPLAY_COMP_RATIO_TYPE – this parameter determines the way of computing the saved storage by archiving. Two possible settings are possible:LOCAL_ONLY: when the saved storage is calculated, ratio for calculating saved storage in external storages is set to 100%, for data archived in the online database the compression ratio was determined during archiving. When the saved storage is calculated, the compression ratio used for calculation is taken and was determined during archiving. In case the parameter is changed, the statistics need to be recalculated with report /dvd/nls_upd_clu_ratio_size.
  • FILTERING_TYPE – determines the way, how is the archived data filtered when accessed. Can be based on RANGE or SETS.
    Possible values: RANGE, SETS
    Default Value: RANGE
  • HNA_UNLOAD_PRIO – determines the Unload Priority of Outboard tables for SAP BW running on SAP HANA. It can be 0 ~ 9, where 0 means not-unloadable and 9 means earliest unload.
    Default value: 9
  • LOAD_MAX_GRAN – determines the maximum number of packages that can be processed at once in the loading via a Data Transfer Process (DTP).
    Possible values:  integer > 0 e.g. 10, 20, 50
    Default value:  5
  • LOAD_USE_ADD_SORTING – when enabled, data loaded from archived WODS is sorted in same order in which it was loaded. This applies when setting has value ‘X’, L mode is used, source WODS is archived. Setting may be switched ON (value X) / OFF (value ‘ ’)

    Default value: ‘ ‘
  • LOAD_PAR_RET – maximum number of finished processes during parallel DTP load.
    Possible values:  integer > 0 e.g. 10, 20, 50
    Default value:  2
  • LOAD_PAR_WP – determines how many parallel jobs will be used for reading from the archive when loading from the archive via DTP. 
    Possible values:  integer >= 0 e.g. 0, 4, 15
    Default value: 2 (parallelization using 2 jobs)
  • NAV_ATTR_BUFFER – size of buffering table when Navigation attribute support is switched on.
    Possible values:  integer > 0 e.g. 10, 20, 50
    Default value: 3000000
  • NAV_ATTR_FILTER_POS – defines the filtering order/ priority when Navigation attribute support is switched on. Value 0 means that filtering on Navigation attribute is done at first then the filtering on other attributes is done. Value 1 represents the opposite scenario.
    Default value: 0
  • NAV_ATTR_SELECTION – parameter to turn the navigation attribute support functionality: on (1) or off (" "). This setting can be edited on InfoProvider level. It is recommended to turn off this parameter for SybaseIQ archiving storage, because needed filtering is done on the database level and there is no need to use the standard Outboard navigational functionality in this case.
    Default value: 1
  • NLS_STATISTICS – this parameter determines if OutBoard Statistics is switched ON (value X) / OFF (value ' ')
    Default value: ON
  • REBUILD_AGGREGATE – this parameter defines if OutBoard aggregates are rebuilt automatically (value X) during the archiving process, or deactivated instead (value ' '). If the automatic rebuild is switched off, the OutBoard aggregates can be activated and filled again using the report /DVD/NLS_FILL_AGGREGATE_IN_BG.
    Default value: ON (X)
  • REP_PAR_WP – this value determines how many work processes are used for reading when data from OutBoard is requested for reporting. For more information see [#Reporting Reporting on archived data].
    Possible values:  integer > 0 e.g. 10, 20, 50
    Default value:  2 (parallelization using 2 jobs)
    Note: For an IQ transparent storage, the parameter for REP_PAR_WP cannot be set to higher than 1.
  • SIZE_DIFF_TRESHOLD – if using a size dependent OutBoard license, after reaching this value of free space, the user will get a warning message by each archiving process or creation of DAP.
    Default value: 60 GB
  • SIZE_TO_MONEY_COEFF – determines how much money costs one GB. Money saved is computed by multiplying SIZE_TO_MONEY_COEFF by storage saved.
    Possible values: integer > 0 e.g. 10, 20, 50
    Default value: 10
  • SIZE_UNIT – the value used as a base unit of measurement for all volumes shown in GUI. If changed, data is recalculated accordingly.
    Possible values:  KB, MB, GB    
    Default value:  GB
  • UPDATE_SIZE_STATISTICS – this parameter determines if object size statistics are updated when archiving or reloading data. In case of substantial archiving requests, recalculation has a noticeable performance impact. Setting may be switched ON (value X) / OFF (value ‘ ’)
    Default value: ON

  • USE_DATA_CLASS_BADI - determines if BAdI will be used to define DATA_CLASS. If the value is 'X' the parameter DATA_CLASS cannot be edited in Settings for a given InfoProvider. (The default value can still be changed.) If the BAdI is used, the implementation for BAdI /DVD/NLS_DETERMINE_DATACLASS has to be created. Parameters of BAdI: iv_dapname – Technical Name of InfoProvider ev_data_class – Data class in technical settings. The output format of the BAdI implementing class method GET_DATA_CLASS should be of type TABART.

...

  • WRITER_AUTO_RELOAD_EMPTY_REQ - enables automatic reload functionality. At the beginning of a DTP load to cube / DSO activation, empty archiving requests are reloaded. Data therefore stays in active table, in the post processing, new archiving requests are created with the same archiving condition.
    Possible values: ON (value X) / OFF (value ' ')
    Default value: ON (X)
  • WRITER_AUTO_RELOAD_THRESHOLD - sets the maximum number of rows for creating new archiving request in post processing. In case of archiving request having more rows than set value, new archiving request has to be created manually.
    Default value: '0'.

Outboard for Analytics with storage management specific settings

Info

Settings are divided into general section with Global settings and InfoProvider specific settings (already described in previous part) and to Storage management part.

...

  1. (0, 3> years – cluster
  2. (3, 6> years – remote system
  3. (6,10> years – file
  4. (10, infinity) – delete

OutBoard on SAP HANA

Info

Datavard's NLS solution is certified for SAP HANA, when using OutBoard with Storage Management on SAP HANA, all archived tables are stored in memory.

...

All archived data are divided into SAP HANA partitions based on NLS Request ID using range partitioning. Range partitioning creates dedicated partitions for certain values or certain value ranges. Range partitioning is used to actively manage the partitioning of a table; partitions may be created or dropped individually.

Language support

English and German are currently supported.

Size Dependent License

If using OutBoard with size dependent license: As of spring release in May 2013, the license can be also size dependent. A size dependent license is based on agreement, prior to Outboard installation.

...