Drill Down Test Case Definition
...
- Description – Add a description of the new Drill Down Variant.
- RFC Destination A – Is the RFC Destination of the system where InfoProvider A is to be read. When the RFC destination is specified in the InfoProvider A field, the F4 help is available.
- InfoProvider A – The technical name for InfoProvider A. F4 help is available for this field.
- Data Access Type A:
- Read Online Data – option to read the only online data in the generated ListCube variant for InfoProvider A.
- Read Online + NLS Data – option to read both the online and the NLS Data in the generated ListCube variant for InfoProvider A. This option is ignored for releases below 7.3 (i.e. only the online data will be read for lower releases).
- Read Only NLS Data – option to read only the NLS data in the generated ListCube variant for InfoProvider A. InfoProviders that are to be read need to have an active DAP created.
- Read NLS Data – Gives you the option to use NLS Data in the ListCube for InfoProvider A.
- Use mat. aggregates – To choose if mat. aggregates should be used in the generated ListCube variant for InfoProvider A.
- Use Conversion Exit – If enabled, on writing into the cluster step, the info objects conversion exit will be applied to the data for InfoProvider A. Important Note: In the current version of Validate the Automated Root Cause Analysis doesn't support this.
- RFC Destination B – Is the RFC Destination of the system where InfoProvider B is to be read. When the RFC destination is specified in the InfoProvider B field, the F4 help is available.
- InfoProvider B – The technical name of InfoProvider B. F4 help is available for this field.
- Data Access Type B:
- Read Online Data – option to only read the online data in the generated ListCube variant for InfoProvider B.
- Read Online + NLS Data – option to read the NLS Data in the generated ListCube variant for InfoProvider B. This option is ignored for releases below 7.3 (i.e. only online data will be read for such releases).
- Read Only NLS Data – option to read only the NLS data for the generated ListCube variant for InfoProvider B. InfoProviders that are to be read need to have an active DAP created.
- Use mat. aggregates – To choose if mat.aggregates are to be used in the generated ListCube variant for InfoProvider B.
- Use Conversion Exit – If enabled, on writing into the cluster step, the info objects conversion exit will be applied to the data for InfoProvider B. Important Note: In the current version of Validate the Automated Root Cause Analysis doesn't support this.
- Drill Down Characteristics – Is the list of characteristics that are going to be used during Drill Down execution for the two specified InfoProviders. F4 help for this select option, but only displays characteristics that exist in both of the InfoProviders. The Order of characteristics is an important select option because it needs to define the order of how they are to be added to the ListCube execution in case any errors are found.
- No BWA Characteristics – You can define the selection of characteristics (as subset of Drill Down Characteristics) because when they are added to the ListCube read during Drill Down execution, the use of BWA is excluded.
- Display Number of Hits – Gives the option to choose if the column 'ROWCOUNT' is to be added to output of ListCube for both of the InfoProviders.
- InfoProvider A Referenced Time point – Is a date and time setting that is used in following way: When a Drill Down Variant references a time point for InfoProvider A, a check is performed before the execution for a load request ID from all of the requests in system that has an update time equal or lower than the specified referenced time point. This request ID is then used in the ListCube read during the Drill Down execution as a filter on the 0REQUID field. Please refer to ('Create new ListCube Variant') section for more information regarding the Reference Time point behavior.
- InfoProvider B Referenced Time point – Performs the same check but for InfoProvider B. Please refer to ('Create new ListCube Variant') section for more information.
- Exclude InfoProvider A old data – changes the behavior of A InfoProvider referenced time point setting, so only the records newer then specified time point would be read.
- Exclude InfoProvider B old data – changes the behavior of B InfoProvider referenced time point setting, so only the records newer then specified time point would be read.
- Excluded Key Figures – Key figures that will be excluded from the selection of both InfoProviders. If the excluded key figure uses a unit and no other non-excluded key figure depends on the unit, it is also excluded from the selection.
- Excluded Units – Units that will be excluded from the selection of both InfoProviders. For all excluded units the appropriate key figures are as well excluded.
...
Warning |
---|
Requirement for Drill Down testing InfoProviders A and B is that both should contain all of the specified Drill Down Characteristics and use the same number of unit/currency InfoObjects. If the Number of Key Figure differs, the missing Key Figure columns are ignored during the comparison. |
Add Existing Drill Down Variant Down Variant
Displays the existing Drill Down variants in the system and you can select one or more variants to be added into the current test case.
...
- Drill Down Characteristics – Is the list of characteristics that are used during the Drill Down execution for the two specified InfoProviders. F4 help for this but only displays the characteristics that exist in both InfoProviders because only these can be used. The order of characteristics as a select option is important because it needs to define the order of how they are added to the ListCube execution in case errors are found.
- No BWA Characteristics – Defines the selection of characteristics (as subset of Drill Down Characteristics) because when these are added to ListCube read during Drill Down execution the use of BWA is excluded.
- Description suffix – Is the suffix to be added in the description of the generated variants. The Description of variants that are generated in the form 'Gen. variant: $INFOPROVIDER_A_NAME <> $INFOPROVIDER_B_NAME'. If a description suffix is specified then the string '- $SUFFIX' is added to the description.
- Data Access Type A:
- Read Online Data – option to only read the online data in all the generated ListCube variants for InfoProviders A.
- Read Online + NLS Data – option to read the NLS Data in all of the generated ListCube variants for InfoProviders A. This option is ignored for releases below 7.3 (i.e. only the online data will be read in lower releases).
- Read Only NLS Data – option to only read the NLS data in all of the generated ListCube variants for InfoProviders A. InfoProviders are to be read needs to have an active DAP created.
- Data Access Type B:
- Read Online Data – option to only read the online data in all of the generated ListCube variants for InfoProviders B.
- Read Online + NLS Data – option to read the online and NLS Data in in all of the generated ListCube variants for InfoProviders B. This option is ignored for releases below 7.3 (i.e. only online data will be read for lower releases).
- Read Only NLS Data – option to only read the NLS data in all of the generated ListCube variants for InfoProviders B. InfoProviders that are to be read needs to have an active DAP created. This option is not release dependent as previous one.
- Use mat. aggregates A – To choose if the mat. aggregates should be used in all the generated ListCube variants for A InfoProviders.
- Use mat. aggregates B – To choose if the mat. aggregates should be used in all the generated ListCube variants for B InfoProviders.
- Use Conversion Exit – To choose if conversion exits are to be used in the generated ListCube variant for InfoProvider A.
- Use Conversion Exit – To choose if conversion exits are to be used in the generated ListCube variant for InfoProvider B.
- Excluded Key Figures – Defines the selection of key figures that will be excluded for all generated variants.
- Excluded Units – Defines the selection of units that will be excluded for all generated variants.
- InfoProviders Selection – In this table, you can specify the pairs of A and B InfoProviders together with their RFC Destinations. For each pair a new Drill Down Variant is generated with all of the settings specified in the header of the screen. It is possible to display the Referenced Time point columns for InfoProviders by changing ALV Layout. These Referenced Time point settings are then used also in generated Drill Down Variants.
...
You can create copies of DrillDown variants by selecting on of multiple variants in the selection table and then clicking on 'Copy DrillDown Variants' toolbar button. For each of the selected variant a new variant is created with exactly the same settings as a source variant.
Copy Variants
Edit Drill Down Variant
You can only edit existing Drill Down variants, if they are not yet used in Test Runs. If a Drill Down Variant is already used in the Test Runs, then its details can be reviewed but not changed.
...